MultiClot®

Viscoelastic Whole-Blood Coagulation

New insights into coagulation dynamics that current systems miss.

Multiclot answers the questions current VET/anti-Xa  testing don’t answer fast enough. Fast, flexible, and insightful, MultiClot features six independent channels engineered for both clinical and research environments. It enables rapid, reproducible assessment of coagulation activation, clot formation, clot stability, and fibrinolysis — with a test menu no other system matches.

Be the first to know when MultiClot launches in ANZ

We respect your privacy. No spam, ever
hand .jpg

Six independent channels. One powerful platform. MultiClot delivers rapid, reproducible whole-blood coagulation analysis — engineered for clinical and research environments.

How Multiclot Works

6941465c6f83272fbaef0234_Blood coagulati

 

MultiClot utilises cup and pin technology with standard citrate whole blood — requiring only 340 µL per test. 

 

MultiClot employs Elastic Motion Thromboelastography with high-sensitivity capacitive signal detection across every channel — engineered for stable, reproducible viscoelastic measurements even in demanding clinical and research environments.

 

By analysing whole blood  MultiClot captures the complete coagulation picture, including the contribution of cellular components, delivering fast and actionable insights for the management of coagulation disorders.

Supported by a growing body of publications, clinical guidelines, and expert recommendations, MultiClot is positioned as a vital tool across both research and clinical settings.

 

An Industry-Leading Test Menu

1

Standard tests

MultiClot offers eight established viscoelastic tests (EX, FIB, AP, IN, HI) covering the full spectrum of coagulation assessment.

Small pack sizes of 10 cartridges support cost-effective testing across both clinical and research settings

2

Anti-Coagulants

MultiClot's standout capability is its dedicated anticoagulant detection — including Russell's viper venom test (RVV) and the ecarin test (ECA) for direct thrombin inhibitors and factor Xa antagonists respectively — enabling precise DOAC monitoring that standard viscoelastic systems cannot match

3

Fibrinolysis

The TPA assay uses recombinant tissue plasminogen activator to identify impaired fibrinolysis — whether due to tranexamic acid (TXA) therapy or intrinsically impaired fibrinolysis (fibrinolytic resistance) — providing critical insight for bleeding management

Reagent Tip Technology – Innovation in action

MultiClot uses innovative reagent tip technology in which each pipette tip carries a dry reagent carrier that reconstitutes automatically when blood is drawn — eliminating manual handling and reducing preparation time.

Unlike fixed four-channel cartridge systems, MultiClot's reagent tip design gives clinicians and researchers complete freedom to select individual assays as needed.

 

This makes MultiClot the only open viscoelastic testing system on the market — offering unmatched diagnostic flexibility across clinical and research applications

69414974fb54d4702561d750_Reagent Tip tec

Dry reagent carrier reconstitutes automatically on blood contact — no manual preparation required.

Product instructions for use

Download the MultiClot Instructions for Use (IFU) document for full technical specifications, assay protocols, and operating procedures

Want to learn more or discuss MultiClot for your institution or research project? Our team is here to help.